Renting the arena
Oslo Spektrum is Norway’s second largest indoor arena positioned in the center of Oslo, with all of Oslo’s facilities close by. From its opening in 1990 the arena has been used for both concerts, musicals, conferences, sport events and fairs. Oslo Spektrum is also an excellent location when it comes to trating your customers and hosting company events. The arena is adeal for both large and smaller events and has the flexibility when it comes to separating and reshaping the arena hall. We offer customized solutions so that you as the promotor is able to host several different smaller events in addition to the mail event.
Our maximum capasity is 11,500 visitors at a concert with the combination of seated and standing audience.
As a promotor or artist in Oslo Spektrum you will have one of Oslo Spektrum’s project manager assigned as your contact person. All of our project managers have high competence within excecuting events, and they have an unique knowledge regarding the arena’s many possibilities.
During preparations and the excecution of events Oslo Spektrum offers key personell such as electrician, house technician, head of security, marketing- and sales personell, personell for the kiosks and bars, house personell welcoming and helping the audience, security staff and cleaning staff.
Contact for booking
For booking or further information, please contact Per-Ole Moen at per-ole@oslospektrum.no or (+47) 98 22 79 12.
Here you will find a detailed fact sheet listing our equipment in house, technical specs and other relevant information.
If you are in need of further information, please contact us by phone or email.
Address
Oslo Spektrum Arena AS
Sonja Henies Plass 2,
N-0185 Oslo,
Norway
Contact information
Front desk phone: +47 22 05 29 00
Booking: MD, Per-Ole Moen +47 98 22 79 12 / per-ole@oslospektrum.no
Venue Details
Capacity | 4 700 permanent seats in the tribune and 5 600 removable chairs on flexible bleachers and floor, gives a total seated capacity of approximately 10 000. Combine seated and standing audience to get a capacity of up to 11 500 pax. |
Arena floor | Effective 3400 m². Additionally there are two side rooms of 2 x 230 m² and a room below the main tribune at approximately 500 m². |
Sound limit | Norwegian regulation: Equivalent noise level three hours 95 dBA. Maximum noise level 110 dBA FAST / 130 dBC PEAK. |
Stage | Adjustable up to 440 m² and height between 48” (≈ 1,2m) and 72” (≈ 1,81m) Standard size 60’ x 40’ x 60” (≈ 18,3m x 12,2m x 1,505m).
For smaller stages, wings, front of house etc. we can offer heights 1’, 2’ and 3’ (≈ 30cm, 60cm and 90cm). |
Stage type | By StageRight Corporation. Imperial measurements. Elements 8’ x 4’. Weight capacity 125 lbs. per square foot (610 kilos per square meter), must be evenly distributed. |
Stage skirt | Yes, 136’ (41,5 meters) in house. |
Barrier | Steel Mojo. 110 meters. |
Bike racks | In house. |
Power supply | On stage level:
400V, three phases, neutral and earth (5 wire). Powerlock connections. Stage right: Four service powerlocks. 1x125A, 2x63A 2x32A CEE Form 400V . Max. 1250A total. Stage left 1: Two service powerlocks. Max. 315A total Stage left 2: One service powerlock. 1x125A, 2x63A, 1x32A CEE Form 400V. Max. 400A total. Upstage center right: 2x63A, 1x32A CEE Form 400V Upstage center left: 2x63A, 1x32A CEE Form 400V FOH: 1x63A CEE Form 400V On catwalks 6th and 7th floor: Stage right: Two service powerlocks. Max. 400A total. Stage left: One service powerlock. Max. 250A total. Bus power: |
Internet LAN/WLAN | Broadband Internet connections available through LAN or WLAN in arena, backstage area and dressing rooms. LAN on RJ45 10/100/1000 MByte with or without DHCP, WLAN in zone SPEKTRUM (802.11 ac/a/g/n). Call for more info. |
Parking | Yes, on request. Please note that most of the parking facilities is own by the city so we must apply some time in advance to use it. Click here for details. |
Load-in | Truck access to stage/arena floor. Load-in gate has 4,5 meters clearance. |
Number of entrances | 10 entrances.
Normally for fully seated shows: Entrances #1, #3 and #7. Normally for GA-shows: Seated audience entrances #1 and #7. GA entrances #5 and #10. Entrance number #2 can be used for early entry and meet & greet. Entrance number #9 is for venue hospitality. |
Distance | Sweden, Gothenburg 290 km. – 3 hrs. and 17 min. drive
Sweden, Stockholm 525 km. – 6 hrs. drive Danmark, Copenhagen 560 km. – 6 hrs. and 20 min. drive Norway, Stavanger 440 km. – 6 hrs. 15 min. drive Norway, Bergen 460 km. – 6 hrs. 30 min. drive Norway, Trondheim 490 km. – 6 hrs. 40 min. drive |
Forklift | Three forklifts, 2 650 – 3 000 kilos. Max. height 4,4 meter. |
Dressing rooms |
All rooms with toilet and shower(s) except room A (only toilet). |
Kitchen/Catering | Located one floor below stage level. Access by two elevators, one slightly larger than the other.
|
Dining area | Up to approximately 60 simultaneously seated. Same location as catering. |
Production Offices | One small (usually for promoter) and one large (can be split into two) on backstage left.
Production office rooms phones, Wi-Fi and hard line on request. |
Wash + Fold Laundry | By promoter. See area ideal for washing machine placement by clicking here. |
Dry cleaners | By promoter. |
Ice supply | By promoter. |
Merchandise | By Scandinavian Concessions Management AB |
Fire doors/gates | Doors and gate openings cannot be blocked or have cables etc. ran through, as these will (and must) be closed in case of a fire alarm. Also, local fire regulations do not allow for this. There are snake runners in most doorways. |
House lights control | Positioned on demand. |
House follow spots | 4 x Robert Juliat Aramis HMI 2,5 kW. |
Follow spots location | Above/behind sections 208-211. Approximately 55 meters (180’) shooting distance. |
Multicore run | In tunnel, see drawing by clicking here. |
Storage | Limited, but depending on seated or GA show there will be possible to store in several rooms, as well as in the back stage corridor. On request. |
Pyro | Must be approved by local authority and supplied by locally licensed company. Health and safety documentation to be approved by venue in advance. |
Rigging | Clearance: 18,3 meters under catwalks, 22,8 meters in between catwalks, high steel 25 meters. No scoreboard.
Rigging access: Catwalks with elevator access. Rigging facilities: 60 movable 500 kg. hoists, 6 gantry cranes with two 2000 kg. hoists each, 6 movable catwalks with 2000 kg. capacity each in addition to permanent beams. |
Rigging regulations | Apply to all personnel engaged in overhead technical rigging, with equipment to be suspended, working in the rigging area, and spotlight operators. The regulations must be read and signed. Hard hats must be worn during the execution of rigging. Hard hats are available at the venue. |
HSE | All subcontractors must document to the organizer that they have HSE procedures in place by submitting a declaration of compliance with the Health, Environmental and Safety Regulations. Subcontractors must also be informed of the rules governing rigging in Oslo Spektrum. |
Draping | Black backdrop. Lots of black draping for dividing the arena and to cover seat kills. |
Doors | Usually 18:30 (6:30 PM). Please note that for a sold out show the venue needs up to 1,5 hours from doors to show start. |
Curfew | 24:00 (12:00 midnight). |
General remarks |
|
Address
Oslo Spektrum Arena AS
Sonja Henies Plass 2,
N-0185 Oslo,
Norway
Contact information
Front desk phone: +47 22 05 29 00
Booking: MD, Per-Ole Moen +47 98 22 79 12 / per-ole@oslospektrum.no
Venue Details
Capacity | 4 700 permanent seats in the tribune and 5 600 removable chairs on flexible bleachers and floor, gives a total seated capacity of approximately 10 000. Combine seated and standing audience to get a capacity of up to 11 500 pax. |
Arena floor | Effective 3400 m². Additionally there are two side rooms of 2 x 230 m² and a room below the main tribune at approximately 500 m². |
Sound limit | Norwegian regulation: Equivalent noise level three hours 95 dBA. Maximum noise level 110 dBA FAST / 130 dBC PEAK. |
Stage | Adjustable up to 440 m² and height between 48” (≈ 1,2m) and 72” (≈ 1,81m) Standard size 60’ x 40’ x 60” (≈ 18,3m x 12,2m x 1,505m).
For smaller stages, wings, front of house etc. we can offer heights 1’, 2’ and 3’ (≈ 30cm, 60cm and 90cm). |
Stage type | By StageRight Corporation. Imperial measurements. Elements 8’ x 4’. Weight capacity 125 lbs. per square foot (610 kilos per square meter), must be evenly distributed. |
Stage skirt | Yes, 136’ (41,5 meters) in house. |
Barrier | Steel Mojo. 110 meters. |
Bike racks | In house. |
Power supply | On stage level:
400V, three phases, neutral and earth (5 wire). Powerlock connections. Stage right: Four service powerlocks. 1x125A, 2x63A 2x32A CEE Form 400V . Max. 1250A total. Stage left 1: Two service powerlocks. Max. 315A total Stage left 2: One service powerlock. 1x125A, 2x63A, 1x32A CEE Form 400V. Max. 400A total. Upstage center right: 2x63A, 1x32A CEE Form 400V Upstage center left: 2x63A, 1x32A CEE Form 400V FOH: 1x63A CEE Form 400V On catwalks 6th and 7th floor: Stage right: Two service powerlocks. Max. 400A total. Stage left: One service powerlock. Max. 250A total. Bus power: |
Internet LAN/WLAN | Broadband Internet connections available through LAN or WLAN in arena, backstage area and dressing rooms. LAN on RJ45 10/100/1000 MByte with or without DHCP, WLAN in zone SPEKTRUM (802.11 ac/a/g/n). Call for more info. |
Parking | Yes, on request. Please note that most of the parking facilities is own by the city so we must apply some time in advance to use it. Click here for details. |
Load-in | Truck access to stage/arena floor. Load-in gate has 4,5 meters clearance. |
Number of entrances | 10 entrances.
Normally for fully seated shows: Entrances #1, #3 and #7. Normally for GA-shows: Seated audience entrances #1 and #7. GA entrances #5 and #10. Entrance number #2 can be used for early entry and meet & greet. Entrance number #9 is for venue hospitality. |
Distance | Sweden, Gothenburg 290 km. – 3 hrs. and 17 min. drive
Sweden, Stockholm 525 km. – 6 hrs. drive Danmark, Copenhagen 560 km. – 6 hrs. and 20 min. drive Norway, Stavanger 440 km. – 6 hrs. 15 min. drive Norway, Bergen 460 km. – 6 hrs. 30 min. drive Norway, Trondheim 490 km. – 6 hrs. 40 min. drive |
Forklift | Three forklifts, 2 650 – 3 000 kilos. Max. height 4,4 meter. |
Dressing rooms |
All rooms with toilet and shower(s) except room A (only toilet). |
Kitchen/Catering | Located one floor below stage level. Access by two elevators, one slightly larger than the other.
|
Dining area | Up to approximately 60 simultaneously seated. Same location as catering. |
Production Offices | One small (usually for promoter) and one large (can be split into two) on backstage left.
Production office rooms phones, Wi-Fi and hard line on request. |
Wash + Fold Laundry | By promoter. See area ideal for washing machine placement by clicking here. |
Dry cleaners | By promoter. |
Ice supply | By promoter. |
Merchandise | By Scandinavian Concessions Management AB |
Fire doors/gates | Doors and gate openings cannot be blocked or have cables etc. ran through, as these will (and must) be closed in case of a fire alarm. Also, local fire regulations do not allow for this. There are snake runners in most doorways. |
House lights control | Positioned on demand. |
House follow spots | 4 x Robert Juliat Aramis HMI 2,5 kW. |
Follow spots location | Above/behind sections 208-211. Approximately 55 meters (180’) shooting distance. |
Multicore run | In tunnel, see drawing by clicking here. |
Storage | Limited, but depending on seated or GA show there will be possible to store in several rooms, as well as in the back stage corridor. On request. |
Pyro | Must be approved by local authority and supplied by locally licensed company. Health and safety documentation to be approved by venue in advance. |
Rigging | Clearance: 18,3 meters under catwalks, 22,8 meters in between catwalks, high steel 25 meters. No scoreboard.
Rigging access: Catwalks with elevator access. Rigging facilities: 60 movable 500 kg. hoists, 6 gantry cranes with two 2000 kg. hoists each, 6 movable catwalks with 2000 kg. capacity each in addition to permanent beams. |
Rigging regulations | Apply to all personnel engaged in overhead technical rigging, with equipment to be suspended, working in the rigging area, and spotlight operators. The regulations must be read and signed. Hard hats must be worn during the execution of rigging. Hard hats are available at the venue. |
HSE | All subcontractors must document to the organizer that they have HSE procedures in place by submitting a declaration of compliance with the Health, Environmental and Safety Regulations. Subcontractors must also be informed of the rules governing rigging in Oslo Spektrum. |
Draping | Black backdrop. Lots of black draping for dividing the arena and to cover seat kills. |
Doors | Usually 18:30 (6:30 PM). Please note that for a sold out show the venue needs up to 1,5 hours from doors to show start. |
Curfew | 24:00 (12:00 midnight). |
General remarks |
|